Package akka.remote.testconductor
Interface TestConductorProtocol.InjectFailureOrBuilder
- 
- All Superinterfaces:
 akka.protobufv3.internal.MessageLiteOrBuilder,akka.protobufv3.internal.MessageOrBuilder
- All Known Implementing Classes:
 TestConductorProtocol.InjectFailure,TestConductorProtocol.InjectFailure.Builder
- Enclosing class:
 - TestConductorProtocol
 
public static interface TestConductorProtocol.InjectFailureOrBuilder extends akka.protobufv3.internal.MessageOrBuilder 
- 
- 
Method Summary
All Methods Instance Methods Abstract Methods Modifier and Type Method Description TestConductorProtocol.AddressgetAddress()optional .Address address = 3;TestConductorProtocol.AddressOrBuildergetAddressOrBuilder()optional .Address address = 3;TestConductorProtocol.DirectiongetDirection()optional .Direction direction = 2;intgetExitValue()optional int32 exitValue = 7;TestConductorProtocol.FailTypegetFailure()required .FailType failure = 1;floatgetRateMBit()optional float rateMBit = 6;booleanhasAddress()optional .Address address = 3;booleanhasDirection()optional .Direction direction = 2;booleanhasExitValue()optional int32 exitValue = 7;booleanhasFailure()required .FailType failure = 1;booleanhasRateMBit()optional float rateMBit = 6;- 
Methods inherited from interface akka.protobufv3.internal.MessageOrBuilder
findInitializationErrors, getAllFields, getDefaultInstanceForType, getDescriptorForType, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof 
 - 
 
 - 
 
- 
- 
Method Detail
- 
hasFailure
boolean hasFailure()
required .FailType failure = 1;- Returns:
 - Whether the failure field is set.
 
 
- 
getFailure
TestConductorProtocol.FailType getFailure()
required .FailType failure = 1;- Returns:
 - The failure.
 
 
- 
hasDirection
boolean hasDirection()
optional .Direction direction = 2;- Returns:
 - Whether the direction field is set.
 
 
- 
getDirection
TestConductorProtocol.Direction getDirection()
optional .Direction direction = 2;- Returns:
 - The direction.
 
 
- 
hasAddress
boolean hasAddress()
optional .Address address = 3;- Returns:
 - Whether the address field is set.
 
 
- 
getAddress
TestConductorProtocol.Address getAddress()
optional .Address address = 3;- Returns:
 - The address.
 
 
- 
getAddressOrBuilder
TestConductorProtocol.AddressOrBuilder getAddressOrBuilder()
optional .Address address = 3; 
- 
hasRateMBit
boolean hasRateMBit()
optional float rateMBit = 6;- Returns:
 - Whether the rateMBit field is set.
 
 
- 
getRateMBit
float getRateMBit()
optional float rateMBit = 6;- Returns:
 - The rateMBit.
 
 
- 
hasExitValue
boolean hasExitValue()
optional int32 exitValue = 7;- Returns:
 - Whether the exitValue field is set.
 
 
- 
getExitValue
int getExitValue()
optional int32 exitValue = 7;- Returns:
 - The exitValue.
 
 
 - 
 
 -