Package akka.remote.testconductor
Interface TestConductorProtocol.InjectFailureOrBuilder
-
- All Superinterfaces:
akka.protobufv3.internal.MessageLiteOrBuilder
,akka.protobufv3.internal.MessageOrBuilder
- All Known Implementing Classes:
TestConductorProtocol.InjectFailure
,TestConductorProtocol.InjectFailure.Builder
- Enclosing class:
- TestConductorProtocol
public static interface TestConductorProtocol.InjectFailureOrBuilder extends akka.protobufv3.internal.MessageOrBuilder
-
-
Method Summary
All Methods Instance Methods Abstract Methods Modifier and Type Method Description TestConductorProtocol.Address
getAddress()
optional .Address address = 3;
TestConductorProtocol.AddressOrBuilder
getAddressOrBuilder()
optional .Address address = 3;
TestConductorProtocol.Direction
getDirection()
optional .Direction direction = 2;
int
getExitValue()
optional int32 exitValue = 7;
TestConductorProtocol.FailType
getFailure()
required .FailType failure = 1;
float
getRateMBit()
optional float rateMBit = 6;
boolean
hasAddress()
optional .Address address = 3;
boolean
hasDirection()
optional .Direction direction = 2;
boolean
hasExitValue()
optional int32 exitValue = 7;
boolean
hasFailure()
required .FailType failure = 1;
boolean
hasRateMBit()
optional float rateMBit = 6;
-
Methods inherited from interface akka.protobufv3.internal.MessageOrBuilder
findInitializationErrors, getAllFields, getDefaultInstanceForType, getDescriptorForType, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof
-
-
-
-
Method Detail
-
hasFailure
boolean hasFailure()
required .FailType failure = 1;
- Returns:
- Whether the failure field is set.
-
getFailure
TestConductorProtocol.FailType getFailure()
required .FailType failure = 1;
- Returns:
- The failure.
-
hasDirection
boolean hasDirection()
optional .Direction direction = 2;
- Returns:
- Whether the direction field is set.
-
getDirection
TestConductorProtocol.Direction getDirection()
optional .Direction direction = 2;
- Returns:
- The direction.
-
hasAddress
boolean hasAddress()
optional .Address address = 3;
- Returns:
- Whether the address field is set.
-
getAddress
TestConductorProtocol.Address getAddress()
optional .Address address = 3;
- Returns:
- The address.
-
getAddressOrBuilder
TestConductorProtocol.AddressOrBuilder getAddressOrBuilder()
optional .Address address = 3;
-
hasRateMBit
boolean hasRateMBit()
optional float rateMBit = 6;
- Returns:
- Whether the rateMBit field is set.
-
getRateMBit
float getRateMBit()
optional float rateMBit = 6;
- Returns:
- The rateMBit.
-
hasExitValue
boolean hasExitValue()
optional int32 exitValue = 7;
- Returns:
- Whether the exitValue field is set.
-
getExitValue
int getExitValue()
optional int32 exitValue = 7;
- Returns:
- The exitValue.
-
-